Correlation Analysis Between Losses with Boiler Opacity and Ambient Air Quality Effect on Capacity of Pulmonary Function of Palm Oil Mill Employees (Comparative Study on PT. AIP and PT. BNS)

Rinno Ferryno, Aras Mulyadi, Nursyirwani Nursyirwani

Abstract


The comparative research was conducted from October 2016 until January 2017 at two companies namely PT. AIP Teluk Siak Factory (TSF) and PT. BNS Mandah Factory (MDF) in Riau Province. The purposes of the research were to analyze the correlation between oil and palm kernel (losses) that is entrained fuel (fibers and shells) with opacity emissions boiler in TSF and MDF, and to analyze the impact of ambient air SO2 levels on capacity pulmonary function palm oil mill employees (TSF and MDF) with controll variables personel protective aquipment, age, smoking habits, and tenure.
Based on the results, The correlation strength of oil loss in fiber cyclone, kernel loss in fiber cyclone, and kernel loss in winowing with boiler opacity in TSF and MDF is low correlation (R value of 0.320). The simultaneous and partial oil loss in fiber cyclone, kernel loss in fiber cyclone, and kernel loss in winowing were not significantly affect the boiler opacity in both factories (F test and t test of significance  > 0.05). R2 value of 10.2% indicates the magnitude of losses effect on opacity. This analysis explains that the losses are not the dominant factor affecting the boiler opacity. The boiler opacity is influenced by quality and balance fuel with oxygen, continuity process in mill and optimization of boiler performance as the operation practice, maintenance and boiler sparepart replacement. The impact of ambient air SO2 levels on capacity pulmonary function when controlled by age and tenure showed significant values (p < 0.05). Age and tenure are factors that differentiate magnitude of the impact of ambient air SO2

levels on capacity pulmonary function. While the impact of ambient air SO2 levels on capacity pulmonary function when controlled by personel protective aquipment (PPE) and smoking habits did not show significant values (p > 0.05) in both factories. PPE and smoking habits are not factors that differentiate magnitude of the impact of ambient air SO2 levels on capacity pulmonary function.


Keywords


Losses; Opacity; SO2 level; Pulmonary Function.

Full Text:

PDF

References


Bachtiyar, C. 2011. Setting Parameter Mesin Pressdengan Metode Respon Permukaan Pada Pabrik Kelapa Sawit. Jurnal Riset Industri 5(2) : 153 –160.

Bindar, Y dan M. Abdulkadir. 2014. Buku Saku Kriteria BoilerRamah Lingkungan. Program Advis Kebijakan untuk Lingkungan Hidup dan Perubahan iklim Kementerian Lingkungan Hidup. Jakarta.

Cahyono, W.E. 2011. Kajian Tingkat Pencemaran Sulfur Dioksida dari Industri di Beberapa Daerah di Indonesia. Berita Dirgantara. 12(4) : 132 –137.

Demay, J. 1997. Wood Waste Boiler Survey. Washington State Department of Ecology Air Quality Program. Olympia.Devani, V dan Marwiji. 2014. Analisis Kehilangan Minyak pada Crude Palm Oil(CPO) dengan Menggunakan Metode Statistical Process Control. Jurnal Ilmiah Teknik Industri. 13(1) : 28 –42.

Lou, J.C, M. Lee, and K.S. Chen. 1997. Plume OpacityCorrelation with Particle and Sulphate from Boiler. Journal of Environment Enginnering American Society of Civil Engineers. 123(7) : 698 –703.

Menteri Lingkungan Hidup. 2007. Peraturan Menteri Lingkungan Hidup No. 07 Tahun 2007 tentang Baku Mutu Sumber Tidak Bergerak. Kementerian Lingkungan Hidup. Jakarta.

Menteri Kesehatan. 2008. Keputusan Menteri Kesehatan No. 1022/Menkes/SK/XI/2008 tentang Pedoman Pengendalian Penyakit Paru Obstruktif Kronik. Kementerian Kesehatan. Jakarta.

Menteri Tenaga Kerja dan Transmigrasi. 2011. Peraturan Menteri Tenaga Kerja dan Transmigrasi No.13 Tahun 2011 tentang Nilai Ambang Batas Faktor Fisika dan Faktor Kimia di Tempat Kerja. Kementerian Tenaga Kerja dan Transmigrasi. Jakarta.

Minamas Plantation. 2010a. Pedoman Teknik Kelapa Sawit. Jakarta.

Minamas Plantation. 2010b. Process Control ManualLaboratorium. Jakarta.

Pearce.2010.Anatomi dan Fisiologi untuk Paramedis.PT Gramedia Pustaka Utama. Jakarta.

Romaski, J.E. 1980. Reducing Opacity by Optimizing Maintenance and Operating Practices. Journal of The Air Pollution Control Association. 30(7) : 748 –754.

Sandra, C. 2013. Pengaruh Penurunan Kualitas Udara terhadap Fungsi Paru dan Keluhan Pernapasan pada Polisi Lalulintas Polwiltabes Surabaya. Jurnal IKESMA. 9(1) : 1 –8.

Suyono, J. 2009. Deteksi Dini Penyakit Akibat Kerja. EGC. Jakarta.

Virgo, G. 2016. Pengaruh Kadar Debu Ambien terhadap Kapasitas Fungsi Paru : Studi Komparatif antara Karyawan pada PT SR dan PT JR. Jurnal Ilmu Lingkungan. 10(2): 179-186.

Widarjono, A. 2009. Ekonometrika Pengantar dan Aplikasi Untuk Ekonomi dan Bisnis. Ekonisia. Jakarta.




DOI: http://dx.doi.org/10.31258/jil.11.1.p.1-13

Refbacks

  • There are currently no refbacks.


Copyright (c) 2017 Pascasarjana Universitas Riau

License URL: Creative Commons Attribution 4.0 International License.